21 maggio 2018

Strong uptake of RayStation Monte Carlo dose engine among proton therapy centers

13 out of 18 RayStation proton sites in clinical operation are now using the proton Monte Carlo (MC) dose engine, and this just a year after it was released. That according to a survey. “The implementation of the RayStation Monte Carlo dose engine has expanded our capability to serve more and a wider range of patients”, says Chang Chang, Director of Physics, Texas Center for Proton Therapy.

One year after RaySearch's first release of the proton MC dose engine in RayStation 6, a survey was sent out to the 18 RayStation proton sites that are in clinical operation with pencil beam scanning. The survey focused on the clinical implementation and use of the new MC dose engine. The answers showed that no less than 13 of the 18 clinics have implemented the MC dose engine in their clinical work flows, with remaining clinics currently in commissioning. Several clinics report that they use the MC dose engine for all patients, while others use it for selected cases where high accuracy is important, such as lung, brain, breast or head and neck.

Peer reviewed research papers are being published showing that Monte Carlo is now considered key for certain cancer types, which has prompted rapid implementation and acceptance. One prime example is “Pencil Beam Algorithms Are Unsuitable for Proton Dose Calculations in Lung”[1] .

Significantly, all clinics that have adopted MC for final dose computation, state that they also use it to drive the optimization. No significant deviations in the clinics validation studies have been reported. Also, all clinics mention very good results in the patient specific QA, especially for fields that employ a range shifter as compared to the results with the analytical dose engine.

Chang Chang, Director of Physics, Texas Center for Proton Therapy says: “The implementation of the RayStation Monte Carlo dose engine has expanded our capability to serve more and a wider range of patients. For example, it enabled us to use larger range shifter to patient air gaps, which streamlined our process in the treatment rooms. In addition, the higher accuracy of the Monte Carlo dose engine allowed us to treat sites like lung, complicated head and neck, and breast with more confidence."

Xavier Vermeren, Chief physicist, West German Proton Therapy Centre Essen says: “Now, when we find a rare deviation in our patient specific QA, we always double check our QA setup and data first. We simply expect the RayStation Monte Carlo dose to be correct, and we have yet to see a field that fails the QA."

Johan Löf, CEO of RaySearch, says: “We are extremely pleased to see that such a high fraction of our customers has implemented the Monte Carlo dose engine in a relative short time. It is also highly rewarding to learn how this new product has increased the quality of the treatments, while at the same time saving time for the physicists thanks to the improved QA results."

News

03/07/2018 News

RaySearch and Eckert & Ziegler BEBIG enter into partnership regarding brachytherapy

RaySearch and Eckert & Ziegler BEBIG, a leading European supplier of brachytherapy products, have signed a partnership agreement. Both the RayStation® treatment planning system and the RayCare* oncology infor [...]

02/07/2018 News

DE.TEC.TOR entra nel gruppo TA Technologic ed Euroimaging

Abbiamo il piacere di comunicare che il 28 Giugno 2018 è stato siglato un accordo per l'incorporazione della società DE.TEC.TOR., leader mondiale nella ricerca e sviluppo di rivelato [...]

22/06/2018 News

Primo paziente in Italia trattato con il sistema Radixact™

Tecnologie Avanzate è lieta di annunciare che oggi è stato trattato il primo paziente in Italia con il nuovo sistema Radixact™  di Accuray, presso il nuovissimo sito dello IOV che si trova&n [...]

Eventi

20gen2017 | Eventi

RayCare Symposium, Roma 26 gennaio 2017

Tecnologie Avanzate è lieta di comunicare che il 26 gennaio organizza a Roma il primo RayCare Symposium, un incontro destinato a presentare in [...]

17set2018 | Radioprotezione e QA

Scuola AIFM di Radioprotezione in ambito sanitario, Roma 17-21 settembre 2018

Tecnologie Avanzate sarà sponsor della "Scuola AIFM di Radioprotezione in ambito sanitario", che avrà luogo a Roma dal 17 al 21 settembr [...]

Video gallery